Origin: 41
Well Data
|
Company Name
|
Esso Australia Pty. Ltd.
|
|
CN
|
|
Well Name
|
MLA-A23A
|
|
WN
|
|
Field Name
|
Turrum
|
|
FN
|
|
Rig:
|
Nabors Rig 453
|
|
CLAB, COUN
|
|
State:
|
Victoria
|
|
SLAB, STAT
|
|
Nation
|
Australia
|
|
NATI
|
|
Field Location
|
Northing 5767924.00 m
|
|
FL
|
|
|
Easting 606863.03 m
|
|
FL1
|
|
|
Bass Strait - Licence VIC / L11
|
|
FL2
|
|
Service Order Number
|
VEA042434
|
|
SON
|
|
Longitude
|
148 13' 15.466" E
|
|
LONG
|
|
Latitude
|
38 13' 49.195" S
|
|
LATI
|
|
Maximum Hole Deviation
|
38.8 (deg)
|
|
MHD
|
|
Elevation of Kelly Bushing
|
27.9 (m)
|
|
EKB
|
|
Elevation of Ground Level
|
-59.0 (m)
|
|
EGL
|
|
Elevation of Derrick Floor
|
27.9 (m)
|
|
EDF
|
|
Permanent Datum
|
M.S.L.
|
Elevation of Permanent Datum 0.0 (m)
|
PDAT, EPD
|
|
Log Measured From
|
D.F.
|
Above Permanent Datum 27.9 (m)
|
LMF, APD
|
|
Drilling Measured From
|
D.F.
|
|
DMF
|
Absent Valued Parameters: CN1, CONT, SECT, TOWN, RANG, APIN
Job Data
|
Date as Month-Day-Year
|
24-Jul-2004
|
|
DATE
|
|
Run Number
|
3
|
|
RUN
|
|
Total Depth - Driller
|
3051.0 (m)
|
|
TDD
|
|
Total Depth - Logger
|
3051.0 (m)
|
|
TDL
|
|
Bottom Log Interval
|
2996.8 (m)
|
|
BLI
|
|
Top Log Interval
|
1450.5 (m)
|
|
TLI
|
|
Current Casing Size
|
9.63 (in)
|
|
CSIZ
|
|
Casing Depth From
|
12.8 (m)
|
|
CDF
|
|
Casing Depth To
|
2978.0 (m)
|
|
CADT
|
|
Casing Grade
|
L-80
|
|
CASG
|
|
Casing Weight
|
26.0 (lbm/ft)
|
|
CWEI
|
|
Bit Size
|
8.50 (in)
|
|
BS
|
|
Date Logger At Bottom
|
25-Jul-2004
|
Time Logger At Bottom 16:45
|
DLAB, TLAB
|
|
Logging Unit Number
|
41
|
Logging Unit Location VEA
|
LUN, LUL
|
|
Engineer's Name
|
J.Bell / K. Hermansen
|
|
ENGI
|
|
Witness's Name
|
C. Menhennitt, A. Ribeiro
|
|
WITN
|
|
Service Order Number
|
VEA042434
|
|
SON
|
Absent Valued Parameters: BSDF, BSDT
Mud Data
|
Drilling Fluid Type
|
KCl / PHPA / Glycol
|
|
DFT
|
|
Drilling Fluid Density
|
9.60 (lbm/gal)
|
Drilling Fluid Viscosity 69.0 (s)
|
DFD, DFV
|
|
Drilling Fluid Loss
|
3.00 (cm3)
|
Drilling Fluid PH 9.10
|
DFL, DFPH
|
|
Borehole Salinity
|
37800.0 (ppm)
|
|
BSAL
|
|
Mud Sample Source
|
Flowline
|
|
MSS
|
|
Resistivity of Mud Sample
|
0.129 (ohm.m)
|
Mud Sample Temperature 25.0 (degC)
|
RMS, MST
|
|
Resistivity of Mud Filtrate Sample
|
0.105 (ohm.m)
|
Mud Filtrate Sample Temperature 25.0 (degC)
|
RMFS, MFST
|
|
Resistivity of Mud Cake Sample
|
0.191 (ohm.m)
|
Mud Cake Sample Temperature 25.0 (degC)
|
RMCS, MCST
|
|
Resistivity of Mud - BHT
|
0.0415 (ohm.m)
|
|
RMB
|
|
Resistivity of Mud Filtrate - BHT
|
0.0338 (ohm.m)
|
|
RMFB
|
|
Maximum Recorded Temperature
|
123.2 (degC)
|
|
MRT
|
|
|
123.2 (degC)
|
|
MRT1
|
|
Date Circulation Stopped
|
22-Jul-2004
|
Time Circulation Stopped 4:10
|
DCS, TCS
|
|
Date Logger At Bottom
|
25-Jul-2004
|
Time Logger At Bottom 16:45
|
DLAB, TLAB
|
Absent Valued Parameters: MRT2, MRT3
PVT Data
|
Borehole Salinity
|
37800.0 (ppm)
|
|
BSAL
|
Absent Valued Parameters: ODEN, GGRA, BO, BW, IBG, BPP, BPT, SGOR
Cement Data
|
Cement Job Type
|
Primary
|
|
CJT
|
Absent Valued Parameters: CTOP, CASN, LCMT, LCVO, CDEN, CWLO, CADD, TCTY, TCV, TCDE, TCWL, TCA
Remarks
|
Correlated to Reeves Dual Laterolog-GR-Density-Neutron log dated 24-Jul-2004. |
R1
|
|
MDT Objectives were to record pressure measurements between 2996.8m and 2535.5m MD (Turrum) and |
R3
|
|
between 1738.0m and 1450.5m MD (Marlin). |
R4
|
|
Tools were conveyed on drill pipe (TLC) due to sticking risk. |
R5
|
|
88 pretests attempted: 65 normal, 12 tight, 6 no seals, 5 unrecognisable. All points are listed and categorised in the Pretest |
R6
|
|
Summary Tables below. |
R7
|
|
Unrecognisable pretests are due to pressure communication through the mudcake to the borehole (fractures or uneven wall). |
R8
|
|
Super charged points have also been counted as unrecognisable. |
R9
|
|
Due to the high number of unrecognisable pretests between 2947.0m and 2942.0m, a repeat was performed at 2959.5m. |
R10
|
|
Both the pump and the second probe was used in the above mentioned interval to get a positive seal. |
R11
|
|
After sealing the formation was observed to be tight. |
R12
|
|
TD not tagged as per normal for TLC operation. |
R13
|
|
Pump was used 9 times during the logging operation. |
R14
|
|
Mud data taken from Baroid Mud Report, dated 24/07/2004 and from Reeves Dual Laterolog-GR-Density-Neutron log dated 24/07/204. |
R15
|
|
Maximum recorded temperature taken from MDT resistivity cell temperature sensor at 2938.0m MD. |
R16
|
|
Maximum deviation was 38.82 deg at 2043.39 m MD, taken from Schlumberger D&M survey dated 21/07/2004. |