WELL DATA: |
R1
|
|
WELL HEAD PRESSURE 4.8 MPa, BOTTOM HOLE TEMPERATURE 106 DEGC |
R2
|
|
TUBING SHOE: 3525.5m, TOOL HOLD-UP DEPTH: 3567m. (LOGGER) |
R3
|
|
WELL DEVIATION: 52 Deg. (AVER), 55 Deg. @ 2850m (MAX).
|
R4
|
|
WIRELINE DATA: |
R5
|
|
** NO STRETCH CORRECTION APPLIED TO ANY DATA ** |
R6
|
|
WHEEL CORRECTION: -7 PARTS PER 10000. |
R7
|
|
CABLE TYPE: 1-32-ZT (ENDS-FIXED STRETCH COEFF. 11.5 X 10-7) |
R8
|
|
|
R9
|
|
LOGGING DATA: |
R10
|
|
NUMBER OF GYRO STATIONS: 20 IN, 130 OUT. |
R11
|
|
TOOL ZERO (RELATIVE TO K.B.):- |
R12
|
|
. RUN #1: +4.5m IN, +1.7m OUT. |
R13
|
|
. RUN #2: +4.5m IN, +3.5m OUT. |
R14
|
|
DIFF BETWEEN DEPTH-SYSTEMS:- |
R15
|
|
. RUN #1: +0.7m IN, +0.1m OUT. |
R16
|
|
. RUN #2: +0.3m IN, -0.1m OUT. |
R17
|
|
|
R18
|
|
OBS: GYRO TOOL HAD TEMPERATURE PROBLEMS AT 1630m COMING OUT. |
R19
|
|
PULLED OUT OF HOLE TO RECONFIGURE TOOL AND RAN BACK TO |
R20
|
|
1720m TO DO OVERLAP AND COMPLETE SURVEY. |
R21
|
|
|
R22
|
|
TOOL DATA: |
R23
|
|
GYRO MEASURE POINT TAKEN AS REFERENCE. 2.28m ABOVE BOT.NOSE |
R24
|
|
CCL(SCHLUM) 5.13m ABOVE TOOL REF. |
R25
|
|
CCL(GYRO. ) 4.16m ABOVE TOOL REF. |
R26
|
|
|
R29
|
|
DIFF. BETWEEN DEPTH SYSTEMS IN DEPTH TRACK.(0->1.0m)
|
R30
|