CREW: TONY GOODWIN, IAN MCINESS, AND IAN WILLIAMS |
R1
|
|
TOOL STRING: SDT(ARRAY)-LDTD-CNTH-SGTL-TCCB-AMS-SAH |
R2
|
|
TOOLSTRING RUN WITH STRENGTHENING SLEEVES ON SONIC AND LDT. |
R3
|
|
TOOL TURNER RUN ON LDT STRENGTHENING SLEEVE, MAX. OD = 6.75" |
R4
|
|
HOLE FINDER RUN AT END OF STRING. |
R5
|
|
SONIC RUN IN LONG LINEAR ARRAY MODE. |
R6
|
|
MAXIUM DEVIATION AT TD PROJECTED AT 89.6 DEG. |
R7
|
|
CALIPER NOT OPEN ON DOWN PASS, CNL CORRECTION=BS |
R8
|
|
GR SPIKES ON DOWN PASS DUE TO FORMATION ACTIVATION- |
R9
|
|
-BY SOURCES WHEN MAKING CONNECTIONS |
R10
|
|
QUICK RELEASE CABLE CLAMP WITH 3000 # SHEAR PIN RUN IN CSES- |
R11
|
|
-(4-1/2" CABLE SIDE ENTRY SUB) |
R12
|
|
.52 SHEAR DISKS RUN ON WET CONNECT |
R13
|
|
BARITE IN MUD EFFECTS THE LDT READINGS. |
R14
|
|
TOOL NOT IN CORRECT ORIENTAION ALL THE WAY ON DOWN PASS. |
R15
|
|
- LDT AND CNT READINGS ARE EFFECTED. |
R16
|
|
MAIN AREA IS FROM 3080 - 3130 ON DOWN PASS. |
R17
|