CREW: TONY GOODWIN, IAN MCINNES, IAN WILLIAMS |
R1
|
|
TOOL STRING: SDT(ARRAY)-LDTD-CNTH-SGTL-TCCB-AMS-SAH |
R2
|
|
TOOLSTRING RUN WITH STRENGTHENING SLEEVES ON SONIC AND LDT. |
R3
|
|
TOOL TURNER RUN ON LDT STRENGTHENING SLEEVE, MAX. OD = 6.75" |
R4
|
|
HOLE FINDER RUN AT END OF WTRING. |
R5
|
|
SONIC RUN IN LOND LINEAR ARRAY MODE. |
R6
|
|
MAXIMUM DEVIATION AT TD PROJECTED AT 89.3 DEG. |
R7
|
|
CALIPER NOT OPEN ON DOWN PASS, CNL CORRECTION=BS |
R8
|
|
GR SPIKES ON DOWN PASS DUE TO FORMATION ACTIVATION- |
R9
|
|
- BY SOURCES WHEN STOPPING TO MAKE CONNECTIONS. |
R10
|
|
QUICK RELEASE CABLE CLAMP WITH 3000 # SHEAR PIN RUN IN CSES- |
R11
|
|
- (4-1/2" CABLE SIDE ENTRY SUB) |
R12
|
|
.52 SHEAR DISKS RUN ON WET CONNECT. |
R13
|
|
BARITE IN MUD SYSTEM EFFECTS THE LDT READINGS. |
R14
|
|
- ERATIC PEF ON UP LDT PASS COMES FROM SMALL DUNES THAT |
R15
|
|
- FORM ON THE LOW SIDE OF THE HORIZONTAL SECTION. |
R16
|
|
- IT CAN BE SEEN ALSO IN THE CALIPER LOG. THE DUNES FORM A |
R17
|
|
- SPECIFIC PERIOD DEPENDING ON THE MUD FLOW VELOCITY DURING |
R18
|
|
- THE DRILLING PROCESS. THE HIGH READINGS COME |
R19
|
|
- FROM THE TOOL SEEING THE BARITE IN BETWEEN THE DUNES. |
R20
|
|
THE DOWN PASS HAS 2 SPLICES, 1 AT 2525 M. AND THE SECOND ONE |
R21
|
|
- AT 2706 M. |
R22
|
|
THE SPLICES COME ON THE REPEAT OR DOWN PASS. |
R23
|
|
NOISE ON THE SONIC DUE TO HOLE CONDITIONS, COAL-WASHOUTS, ET |
R24
|